Rating | 105 deg C, 300 Vac, 60 or 80 degrees C oil resistnat (optional), Cable flame. |
|
Conductor | 18 AWG - 2 AWG min. stranded, tinned or bare copper. |
|
Insulation | TPE |
| AWG Size | minimum average thickness | minimum thickness at any point |
| 18-8 AWG | 30 mils | 27 mils |
| 7-2 AWG | 45 mils | 40 mils |
|
Assembly | Two or more, individually insulated conductors or groups of insulated conductors to form a round cable. The length of lay of the twisted conductors or groups is not specified. Fillers may be use in a cable but are not required. Barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented olyethylene terephthalate; or thermoplastic-tape wrap.
|
|
Jacket | TPE |
| Diameter of Cable under jacket | minimum average thickness | minimum thickness at any point |
| 0.700 or less | 30 mils | 23 mils |
| 0.701-1.000 | 45 mils | 36 mils |
| 1.001-1.500 | 60 mils | 48 mils |
| 1.501-2.500 | 80 mils | 64 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. May be marked "60C Oil Resistant" and/or "80C Oil Resistant". |
|