APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21558 Issued:2007-05-17
Revised:2019-11-07
Style 21558 Multiple-Conductor Cable using Non-Integral Jacket

Rating105 deg C, 300 Vac, Cable flame.
Conductor18 AWG - 2 AWG min. solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional inner layer.
BraidOptional.
JacketTPE
dia
0.700 inches or less30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.