| Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 36 AWG - 16 AWG minimum, solid or stranded round, tinned or bare. |
|
| Insulation | Extruded mPPE, 7 mils minimum average thickness, 6 mils minimum thickness at any point. |
|
| Assembly | Two or more insulated singles laid parallel to form a flat cable, singles retained by heat-bonded sections of at least 1 inch long and at intervals of 2 to 4 inches. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring. |
|