APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21560 Issued:2007-05-23
Revised:2012-03-30
Style 21560 Bonded Extruded Flat Ribbon Cable

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 16 AWG minimum, solid or stranded round, tinned or bare.
InsulationExtruded mPPE, 7 mils minimum average thickness, 6 mils minimum thickness at any point.
AssemblyTwo or more insulated singles laid parallel to form a flat cable, singles retained by heat-bonded sections of at least 1 inch long and at intervals of 2 to 4 inches.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024