APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21564 Issued:2007-07-18
Revised:2012-04-16
Style 21564 Multiple-conductor cable using non-integral jacket.

Rating90 deg C, 600 Vac, 60 C Oil Resistant, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more insulated conductors.
ShieldOptional.
CoveringOptional inner layer.
JacketExtruded XLPE, 20 mils minimum average thickness, 16 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.