APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21566 Issued:2007-07-24
Revised:2012-04-24
Style 21566 Multiconductor Cable with Non-Integral Extruded Jacket.

Rating90 deg C, 300 Vac, Horizontal flame.
Conductor32 AWG - 10 AWG min. solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
Covering(Optional) A 6 mil or heavier covering may be extruded over the conductor assembly.
BraidOptional.
JacketPUR - POLYURETHANE, 30 mils min average, 24 mils minimum at any point. See facing page for compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024