APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21572 Issued:2007-08-21
Revised:2011-09-09
Style 21572 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 30 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more insulated singles. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. Diameter of assembly under jacket 1.500 inches maximum.
ShieldOptional.
JacketExtruded TPE, 13 mils minimum average thickness, 10 mils minimum thickness at any point.
Misc.Flat Jacketed Cable Construction - Optional. Two or more jacketed cables may be laid parallel and joined by web to form a flat cable. If the construction is separable, jacket thickness measurement shall be made after ripping.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external wiring of Class 2 circuit.