APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21576 Issued:2007-10-15
Revised:2019-11-07
Style 21576 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 1000 Vac, Optional 60 deg C or 80 deg C Oil, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
CoveringOptional inner layer.
BraidOptional.
JacketExtruded TPU
Dia
0.700 inches or less15 mils minimum average thickness12 mils minimum thickness at any point
0.701 - 1.500 dia30 avg24 min
1.501 - 2.500 dia45 avg36 min
2.501 dia and larger60 avg54 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024