Rating | 80 deg C, 1000 Vac, Optional 60 deg C or 80 deg C Oil, Horizontal flame. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable.
A flat or oval cable may also be constructed with not more
than three rows of single conductors or groups of
conductors. The length of lay of the twisted conductors or
groups is not specified. Fillers may be used in a cable but
are not required. A barrier layer, if employed, may be a
fibrous wrap serving, or braid; paper; nylon; oriented
polyethylene terephthalate; or thermoplastic-tape wrap.
Such a barrier layer would serve to protect the cable during
further processing and would be applied immediately over the
twisted assembly of individual conductors or groups of
conductors. |
|
Shield | Optional. |
|
Covering | Optional inner layer. |
|
Braid | Optional. |
|
Jacket | Extruded TPU |
| Dia |
| 0.700 inches or less | 15 mils minimum average thickness | 12 mils minimum thickness at any point |
| 0.701 - 1.500 dia | 30 avg | 24 min |
| 1.501 - 2.500 dia | 45 avg | 36 min |
| 2.501 dia and larger | 60 avg | 54 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|