| Rating | 80 deg C, 150 Vac, Horizontal flame. |
|
| Conductor | 50 AWG - 10 AWG min. solid or stranded round. |
|
| Insulation | Extruded FRPE, 10 mils minimum average thickness, 9 mils minimum thickness at any point. |
|
| Assembly | Two insulated conductors laid in parallel |
|
| Shield | Heat-sealed Aluminum/polyester, provided over the assembly, 1 mils average thickness, 0.25 inch wide, minimum 25% overlap. |
|
| Jacket | Optional. Heat-sealed TPES tape wrap, 0.5 mils average thickness, 0.25 inch wide, minimum 25% overlap. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring. |
|