Rating | 80 deg C, 300 Vac, Internal Wiring. |
|
Conductor | 32 AWG - 10 AWG min. solid or stranded round, tinned or bare copper. |
|
Insulation | HDPE, 9 mils minimum average thickness, 8 mils minimum thickness at any point. |
|
Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. Jacketed groups may be laid parallel to form a complete flat cable with or without a web.
|
|
Shield | Aluminum/mylar foil, 2 mils average thickness, 30% overlap. |
|
Jacket | TPE |
| dia of Cable under jacket 0.700 inches or less | 30 mils min average | 24 mils minimum at any point |
| 0.701-1.000 dia | 45 avg | 36 min |
| 1.001-1.500 dia | 60 avg | 48 min |
| 1.501-2.500 dia | 80 avg | 64 min |
| 2.501-4.000 dia | 110 avg | 88 min |
| 4.001 dia and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|