APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21585 Issued:2008-01-31
Revised:2011-10-20
Style 21585 Multiple-conductor cable using non-integral jacket.

Rating150 deg C, 300 Vac Horizontal flame.
Conductor36 AWG - 20 AWG min. solid or stranded.
Assembly2-6 individually insulated conductors or groups of conductors cabled together into a round cable. Lay not specified.
InsulationExtruded ETFE, 9 mils min average, 8 mils min at any point
ShieldAluminum polyester tape shield, min 10% overlap, 1.0 mils min, with drain wire over the individual or groups of conductors.
CoveringExtruded ETFE (Ethylene and Tetratluroethylene), or PVDF 9 mils min avg., 7 mils min at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseResistance wire for heating mats where the acceptability is determined by Underwriters Laboratories.