APPLIANCE WIRING MATERIAL
Subj.758
Section
2
Page
21591
Issued:
2008-05-14
Revised:
2008-05-27
Style
21591
Jacketed Cable
Rating
80 deg C, 300 Vac, Horizontal flame.
Insulation
Labeled or complying with manufacturer's AWM procedure.
Assembly
Two or more insulated conductors laid parallel or assembled round. Tapes, fillers, drain wire and/or binder optional. Cable may be either straight or helically coiled
Shield
Optional.
Jacket
PUR - POLYURETHANE, 20 mils min average, 16 mils minimum at any point.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal wiring.