APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21594 Issued:2008-06-20
Revised:2012-04-18
Style 21594 Multople-conductor cable using non-integral jacket

Rating90 deg C, 300 Vac.
Conductor36 AWG - 20 AWG min. solid or stranded round, tinned or bare copper.
InsulationETFE, 9 mils min average, 8 mils min at any point
Assembly2-6 individually insulated conductors or groups of conductors cabled together, with an optional mylar tape binder, into a round cable.
ShieldBraid (80 percent min coverage tinned or bare copper or stainless steel) or Aluminum polyester tape (min 25% overlap, 1.5 mils min thickness, with drain wire) over the individual or groups of conductors.
CoveringHDPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing as Resistance Heater Wire where the acceptability has been determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024