| Rating | 90 deg C, 300 Vac. |
|
| Conductor | 36 AWG - 18 AWG min. solid or stranded round. |
|
| Insulation | Extruded ETFE, 9 mils min average, 8 mils min at any point |
|
| Assembly | 2-6 individually insulated conductors or groups of conductors cabled together into a round cable. |
|
| Shield | Braid (80 percent min coverage tinned or bare copper or stainless steel) or Aluminum polyester tape (min 25% overlap, 1.0 mil min thickness, with drain wire) over the individual or groups of conductors. |
|
| Covering | Extruded XLHDPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | For Further Processing as Resistance Heater Wire where the acceptability has been determined by Underwriters Laboratories Inc.
|
|