Rating | 150 deg C, 300 Vac, Cable flame. |
|
Conductor | 30 AWG - 8 AWG, solid or stranded. |
|
Insulation | Extruded ETFE, 10 mils min average, 9 mils minimum at any point. |
|
Assembly | Two or more insulated conductors.Twisted singles or groups of twisted singles twisted together, or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG size. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. |
|
Shield | Metal braid. |
|
Jacket | Extruded ETFE |
| Dia. under Jacket in inch | Minimum average thickness mils | Minimum thickness at any point mils |
| 0.250 or less | 8 | 6 |
| 0.251 - 0.350 | 10 | 8 |
| 0.351 - 0.500 | 13 | 10 |
| 0.501 - 0.700 | 15 | 12 |
| 0.701 - 1.500 | 20 | 16 |
| Major diameter if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal and external use. |
|