APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21607 Issued:2008-10-02
Revised:2014-05-27
Style 21607 Multiconductor Cable with extruded Non-integral Jacket

Rating90 deg C, 300 V ac.
Conductor50 AWG - 19 AWG, solid or stranded round.
InsulationLabeled Style 10637, ETFE 9 mils min average 8 mils minimum thickness at any point.
Assembly2 conductors twisted together.
ShieldStainless steel braid with minimum 85% coverage, or a tape foil minimum 1.5 mils thick 0.35 inch width with minumum 25% overlap and a drain wire.
CoveringNone.
BraidNone.
JacketTPU - POLYURETHANE, 12 mils min average, 10 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing into Cables.

UL and the UL Logo are trademarks of UL LLC © 2024