APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21609 Issued:2000-10-08
Revised:2012-04-25
Style 21609 Multiple-conductor cable using non-integral jacket.

Rating90 deg C, 600 Vac, Horizontal flame.
Conductor36 AWG - 10 AWG min. solid or stranded round.
InsulationExtruded XLPE, 6 mils minimum average thickness and 5 mils minimum thickness at any point.
AssemblyConsists of two or more insulated conductors cabled together. The conductors or groups of conductors may be laied parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional - A 6 mil or heavier covering may be extruded over the conductor assembly.
JacketExtruded TPU, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances.

UL and the UL Logo are trademarks of UL LLC © 2024