| Rating | 90 deg C, 1000 Vac, Horizontal flame. |
|
| Conductor | 36 AWG - 10 AWG minimum, solid or stranded round. |
|
| Insulation | Extruded XLPE, 6 mils minimum average thickness, 5 mils minimum thickness at any point. |
|
| Assembly | Two or more insulated conductors cabled together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size. Manufacturer shall maintain a complete description of each assembly. |
|
| Shield | Optional. |
|
| Covering | Optional inner layer. |
|
| Braid | Optional. |
|
| Jacket | Extruded TPU, 15 mils minimum average thickness, 12 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring of appliances. |
|