APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21610 Issued:2008-10-08
Revised:2012-03-30
Style 21610 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating90 deg C, 1000 Vac, Horizontal flame.
Conductor36 AWG - 10 AWG minimum, solid or stranded round.
InsulationExtruded XLPE, 6 mils minimum average thickness, 5 mils minimum thickness at any point.
AssemblyTwo or more insulated conductors cabled together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional inner layer.
BraidOptional.
JacketExtruded TPU, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances.

UL and the UL Logo are trademarks of UL LLC © 2024