Rating | 200 deg C, 150 Vac, Cable flame. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two insulated conductors laid parallel or two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A binder and/or fillers may be employed. |
|
Shield | Optional. |
|
Covering | Optional. |
|
Jacket | Extruded FEP. |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.250 inch or less | 8 mils | 6 mils |
| 0.251-0.350 inch | 10 mils | 8 mils |
| 0.351-0.500 inch | 13 mils | 10 mils |
| 0.501-0.700 inch | 15 mils | 12 mils |
| 0.701-1.500 inch | 20 mils | 16 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment |
|