Rating | 200 deg C, 300 Vac, Cable flame. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two insulated conductors laid parallel or two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A binder and/or fillers may be employed. |
|
Covering | Optional. |
|
Shield | Optional. |
|
Jacket | Extruded FEP |
| dia under jacket in inches | Min average thickness mils | Min thickness at any point mils |
| 0-0.250 | 8 | 6 |
| 0.251-0.350 | 10 | 8 |
| 0.351-0.500 | 13 | 10 |
| 0.501-0.700 | 15 | 12 |
| 0.701-1.500 | 20 | 16 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|