Rating | 90 deg C, 300 Vac, Cable flame. |
|
Conductor | 36 AWG - 20 AWG, solid or stranded. |
|
Insulation | Extruded FEP, 11 mils minimum average, 10 mils minimum at any point. |
|
Assembly | Two insulated conductors. Barrier layer and/or fillers optional. |
|
Shield | Optional. |
|
Covering | Optional. |
|
Jacket | Extruded PVC, 23 mils minimum average, 18 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal and external wiring. |
|