APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21635 Issued:2009-06-05
Revised:2011-08-05
Style 21635 Multiple-Conductor Cable with Extruded Non-Integral Jacket

Rating105 deg C, 600 Vac, Cable flame
Conductor50 AWG - 10 AWG solid or stranded
InsulationLabeled or complying with manufacturer's AWM procedure
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A binder and/or fillers may be employed
ShieldBraid, in accordance with the Standard
JacketExtruded PVC
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseExternal interconnect of appliances