APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21638 Issued:2009-06-19
Revised:2012-04-17
Style 21638 Multiple-conductor cable using non-integral jacket.

Rating150 deg C, 30 Vac, Cable flame.
ConductorTwo or more, 40 AWG - 10 AWG, solid or stranded.
InsulationExtruded FEP, 2 mils minimun average thickness, 1 mil minimum thickness at any point.
ShieldOptional - Metal
CoveringOptional - FEP Tape may be applied over the insulated singles and/or between the shield.
BraidOptional - Metal
JacketExtruded FEP, 8 mils minimum average thickness, 6 mils minimum at any point. In accordance with UL758, Table 13.2.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnect of appliances.