APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21644 Issued:2009-07-21
Revised:2019-11-07
Style 21644 Multiconductor Cable with Non-integral Jacket

Rating90 deg C, -40 deg C, 300V, Cable flame.
Conductor40 AWG - 10 AWG, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure, rated minimum 90C, 300V, -40C.
AssemblyTwo or more conductors cabled together with optional optical fiber members and/or optional fillers. Optional PTFE binder tapes may be provided over single conductors, groups of conductors, groups of optical fiber members and/or over the complete cable core.
ShieldOptional.
CoveringPTFE BINDER.
JacketExtruded TPU, See Facing Page for Compound.
dia. in inches
0.700 or less40 mils min average32 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min.
1.501-2.500 dia80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnect of appliances.

UL and the UL Logo are trademarks of UL LLC © 2025