APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21647 Issued:2009-08-20
Revised:2011-11-01
Style 21647 Multi-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM procedure having a minimum rating of 80 deg C and 300 Vac.
AssemblyTwo or more coaxial cables laid parallel to form a flat cable. Each coaxial cable consists of an insulated conductor, shield and jacket.
ShieldRequired, over each insulated conductor.
JacketExtruded mPPE.
Diameter of core assembly under jacketMinimum average thickness milsMinimum at any point mils
0.700 inch or less3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.