APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21650 Issued:2009-09-04
Revised:2011-10-17
Style 21650 Multiple conductor cable using extruded non-integral jacket.

Rating150 deg C, 300 Vac, Horizontal flame, Cable flame. Optional - 60 or 80 deg C Oil, Gasoline Resistant.
Conductor50 AWG - 10 AWG min. solid or stranded round.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo insulated conductors laid parallel or two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A binder, fillers and/or an extruded filler of Silicone Rubber may be employed.
ShieldOptional.
CoveringOptional. Extruded FEP.
BraidOptional.
JacketExtruded FEP
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.250 inches or less8 mils6 mils
0.251-0.350 inches10 mils8 mils
0.351-0.500 inches13 mils10 mils
0.501-0.700 inches15 mils12 mils
0.701-1.500 inches20 mils16 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or Internal wiring of appliances.

UL and the UL Logo are trademarks of UL LLC © 2024