Rating | 150 deg C, 300 Vac, Horizontal flame, Cable flame. Optional - 60 or 80 deg C Oil, Gasoline Resistant. |
|
Conductor | 50 AWG - 10 AWG min. solid or stranded round. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two insulated conductors laid parallel or two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A binder, fillers and/or an extruded filler of Silicone Rubber may be employed. |
|
Shield | Optional. |
|
Covering | Optional. Extruded FEP. |
|
Braid | Optional. |
|
Jacket | Extruded FEP |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.250 inches or less | 8 mils | 6 mils |
| 0.251-0.350 inches | 10 mils | 8 mils |
| 0.351-0.500 inches | 13 mils | 10 mils |
| 0.501-0.700 inches | 15 mils | 12 mils |
| 0.701-1.500 inches | 20 mils | 16 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection or Internal wiring of appliances. |
|