APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2166 Issued:1959-05-01
Revised:2011-09-22
Style 2166 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor20 AWG - 16 AWG, using No. 30 AWG or smaller tinned copper strands.
InsulationExtruded PE and extruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyThree conductors, one 20 AWG PE insulated conductor and two 16 AWG PVC insulated conductors. Over the PE insulated conductor a copper shielding shall be applied as a braid or wrap. Conductors shall be twisted together with a maximum lay of 2 1/2 inches. The use of fillers is optional, valleys between conductors may show through jacket.
ShieldOver the PE insulated conductor, copper braid or wrap.
FillerOptional.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseOrgan Cable.