APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21662 Issued:2009-12-03
Revised:2012-04-04
Style 21662 Multiple-conductor cable using non-integral jacket.

Rating90 deg C, 300 V ac, Horizontal flame.
Conductor32 AWG - 10 AWG, Solid or stranded.
InsulationExtruded TPE, 12 mils min average, 10 mils minimum at any point.
AssemblyTwo or more insulated conductors.
ShieldOptional.
CoveringOptional.
JacketExtruded TPE, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.