APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21668 Issued:2010-04-09
Revised:2012-04-17
Style 21668 Multiconductor Cable with Extruded Non-Integral Jacket

Rating120 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 9 AWG, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more insulated conductors, filler optional.
ShieldOptional.
CoveringOptional.
JacketTPE.
Major diameter of assembly under Jacket*Minimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701 - 1.000 inch45 mils36 mils
1.001 - 1.500 inch60 mils48 mils
1.501 - 2.500 inch80 mils64 mils
2.500 inch or larger110 mils88 mils
* - Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024