APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2167 Issued:1959-05-01
Revised:2012-04-04
Style 2167 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, FT2 flame.
ConductorA and B - 18 AWG and C, D and E - 20 AWG, each consisting of 30 AWG strands of metal coated copper.
InsulationExtruded PVC, 30 mils minimum average, 27 mils minimum at any point. Same as for Type SJT cord. Colors: A-Gray, B-Blue, C-Red, D-Black, E-White.
AssemblyFive conductors. Conductor E shall be provided with a brown cotton braid over the insulation. C & D shall be twisted together with a 1 1/2 inch max. right-hand lay. A, B and E and the combined Conductors C & D, together with cotton or jute fillers shall be twisted with a 3 1/2 inch max. left-hand lay. A cotton serve shall be applied over the conductor assembly.
JacketSame as for Type SJT cord.
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseFor Use with Electric Organ.

UL and the UL Logo are trademarks of UL LLC © 2024