Rating | 60 deg C, 300 Vac, FT2 flame. |
|
Conductor | A and B - 18 AWG and C, D and E - 20 AWG, each consisting of 30 AWG strands of metal coated copper. |
|
Insulation | Extruded PVC, 30 mils minimum average, 27 mils minimum at any point. Same as for Type SJT cord. Colors: A-Gray, B-Blue, C-Red, D-Black, E-White. |
|
Assembly | Five conductors. Conductor E shall be provided with a brown cotton braid over the insulation. C & D shall be twisted together with a 1 1/2 inch max. right-hand lay. A, B and E and the combined Conductors C & D, together with cotton or jute fillers shall be twisted with a 3 1/2 inch max. left-hand lay. A cotton serve shall be applied over the conductor assembly. |
|
Jacket | Same as for Type SJT cord. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General |
|
Use | For Use with Electric Organ. |
|