APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21670 Issued:2010-04-09
Revised:2011-11-10
Style 21670 Multiple-conductor cable using non-integral jacket

Rating120 deg C, 1000 Vac, Horizontal flame.
Conductor36 AWG - 9 AWG, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more insulated conductors, filler optional.
ShieldOptional.
CoveringOptional.
JacketExtruded TPE.
Major diameter of assembly under Jacket*Minimum average thicknessMinimum thickness at any point
0.700 inch or less45 mils36 mils
0.701 - 1.000 inch60 mils48 mils
1.001 - 1.500 inch80 mils64 mils
1.501 - 2.500 inch110 mils88 mils
2.500 inch or larger140 mils112 mils
* - Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024