Rating | 60 deg C, 300 Vac, Horizontal flame. |
|
Conductor | A and B - 18 AWG, and C, D, and E - 20 AWG, each consisting of 30 AWG strands. |
|
Insulation | Same as for Type SJT Cord. Colors: A-Gray, B-Blue, C-Red, D-Black, E-White or Brown.
|
|
Assembly | Five conductors, same as for Type SJT cord.
Conductor E when white, shall be provided with a brown cotton braid over the insulation. A tinned-copper braid or spiral wrap shield (four 36 AWG strands in each of 16 carries) shall be applied over the cotton braid or insulation. C and D shall be twisted together with a 1-1/2 inches max. right-hand lay. A, B, and E and the combined conductors C and D, together with cotton or jute fillers shall be twisted with a 5 inches max. left-hand lay. A cotton serve shall be applied over the conductor assembly. |
|
Jacket | Same as for Type SJT Cord. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General |
|
Use | For Use with Electric Organs. |
|