Rating | 105 deg C, 300 Vac, Horizontal flame |
|
Conductor | 40 AWG - 20 AWG solid or stranded |
|
Insulation | Extruded Polyolefin blend, 9 mils minimum average thickness, 7 mils minimum thickness at any point. Flat, Extruded Top and/or bottom layers may form ridges over conductors, 35 mils minimum distance between conductors, See Facing Page. |
|
Assembly | Two or more conductor, Flat Cable folded or spiraled layers. Section may be slit into singles. Fillers optional. Overall Cable may be Flat or Round. |
|
Shield | Optional |
|
Jacket | Extruded Polyolefin, See Facing Page. |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701-1.000 inch | 45 mils | 36 mils |
| 1.001-1.500 inch | 60 mils | 48 mils |
| 1.501-2.500 inch | 80 mils | 64 mils |
| |
| Cable is flat or round. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General |
|
Use | Internal wiring of appliances |
|