APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21684 Issued:2010-05-06
Revised:2012-05-07
Style 21684 Multiple Cable using non-integral jacket

Rating105 deg C dry, 90 deg C Wet, 600 Vac, Cable flame, 720 hour Sunlight Resistance. Optional: Oil Res 75C.
InsulationLabeled or complying with manufacturer's AWM procedure with appropriate ratings.
AssemblyTwo insulated conductors laid parallel or two or more insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional inner layer - PVC with min average thickness 6 mils, min thickness at any pont 5 mils, provided over the conductor core.
JacketPVC.
Dia of Cable under jacketMin averageMinimum at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnect of appliances and Internal Wiring where exposed to temperatures not exceeding 105 deg C in dry location and 90 deg C in wet location and Sunlight Resistance. Optional: Oil Res 75C.

UL and the UL Logo are trademarks of UL LLC © 2024