APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21687 Issued:2010-05-24
Revised:2011-10-28
Style 21687 Jacketed cable

Rating80 deg C, 30 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo to six subunits laid parallel and joined together with or without a web to form a flat cable. Each subunit consists of two or more insulated conductors and jacket, with optional filler, covering and shield. Width or thickness of web not specified. Maximum diameter of assembly under jacket of subunit 2.500 in.
ShieldOptional, provided in subunit.
CoveringOptional, provided in subunit.
JacketPUR, 15 mils minimum average, 12 mils minimum at any point. For rippable construction, jacket thickness shall be measured after ripping.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring in or with Class 2 circuits.

UL and the UL Logo are trademarks of UL LLC © 2024