APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21693 Issued:2010-05-28
Revised:2011-10-26
Style 21693 Flat ribbon cable using non-integral covering.

Rating105 deg C, 600 Vac, Horizontal flame.
Conductor32 AWG - 16 AWG min, solid or stranded.
InsulationPVC, 8 mils minimum average thickness, 7 mils minimum thickness at any point. For rippable construction, thickness shall be measured after ripping.
Assembly2 to 150 conductors laid parallel and in one plane. This forms a flat cable with a single row of conductors having a 0.5 in. maximum width web between insulated conductors.
ShieldOptional.
CoveringPVC, 9 mils minimum average thickness, 7 mils minimum thickness at any point, 80 mils maximum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.