APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21694 Issued:2010-06-03
Revised:2011-11-10
Style 21694 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 600 Vac, Horizontal flame.
ConductorSolid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
ShieldOptional.
CoveringOptional.
JacketExtruded PVC. 30 mils minimum average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances.