APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2170 Issued:1959-05-01
Revised:2008-05-27
Style 2170 SJT Cord.

Rating60 deg C, 300 Vac, FT2 flame.
Conductor22 - 20 AWG, each consisting of No. 30 AWG or smaller tinned copper strands.
InsulationPVC, 15 mils min average, 14 mils minimum at any point. A, B and C shall have a nominal 15 mil wall, D and E shall have a nominal 30 mil inch wall.
AssemblyFive conductors, same as type SJT. A, B and C No. 22 AWG, D and E No. 20 AWG, each consisting of No. 30 AWG or smaller tinned copper strands. A, B and C shall have a nominal 15 mil wall, D and E shall have a nominal 30 mil inch wall. All conductors shall be provided with a lacquered rayon braid. Conductors A, B, and C shall be provided with a copper braid shield (six No. 40 AWG strands in each of sixteen carriers, eighteen picks per inch). The conductors shall be combined with cotton or jute fillers and twisted together with a 3 1/2 inch max. right-hand lay. A cotton serve shall be applied over the conductor assembly.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseFor Use with Electric Organs.
 
UL and the UL Logo are trademarks of UL LLC © 2024