APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21704 Issued:2010-07-30
Revised:2011-11-24
Style 21704 Multiple conductor cable using non-integral jacket.

Rating105 deg C, 1000 Vac, Cable flame, Optional 60C Oil Resistant & Gasoline Resistant.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional inner layer.
JacketPVC
Diameter of round assembly under jacket or equivalent diameter of flat assembly under jacketMinimum average thicknessMinimum thickness at any point
0 - 0.400 in30 mils24 mils
0.401 - 0.700 in30 mils24 mils
0.701 - 1.000 in45 mils36 mils
1.001 - 1.500 in60 mils48 mils
1.501 - 2.500 in80 mils64 mils
- For flat assembly, calculated as 1.1284 x (TW)1/2 in which T is the thickness of the assembly under the jacket and W is the width of the assembly under the jacket.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring

UL and the UL Logo are trademarks of UL LLC © 2024