This Style Page is no longer being updated. It is for historic reference only. Please visit: Search - Appliance Wiring Material - Company - Product iQ for the latest Style Page information 
Subj.758 Section 2 Page 21706 Issued:2010-08-24
Revised:2012-04-02
Style 21706 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG - 16 AWG minimum, solid or stranded round.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more conductors, fillers optional.
ShieldOptional.
JacketExtruded MPPE-PE, 21 mils minimum average thickness, 17 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances.

UL and the UL Logo are trademarks of UL LLC © 2026