APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21707 Issued:2010-08-25
Revised:2011-08-11
Style 21707 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 30 Vac, Cable flame
Conductor50 AWG - 16 AWG solid or stranded
InsulationLabeled or complying with manufacturer's AWM procedure or Extruded TPE, 8 mils minimum average thickness, 7 mils minimum thickness at any point
AssemblyTwo or more conductors, fillers optional
ShieldOptional
JacketExtruded TPE
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.400 inch or less24 mils20 mils
0.401-0.700 inch30 mils24 mils
0.701-1.500 inch45 mils36 mils
1.501-2.500 inch60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseExternal interconnect of appliances or Internal Wiring