Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 17 or 16 AWG, solid or stranded.
Conductive core - Extruded TPE compound filled with special carbon, provided over each conductor and between conductors. Not evaluated as self-regulating heating core. |
|
Insulation | Inner Insulation - TPU, 12 mils minimum average thickness, 11 mils minimum thickness at any point.
Outer Insulation - TPE, 18 mils minimum average thickness, 16 mils minimum thickness at any point. Each insulation layer separable. |
|
Assembly | Two conductors laid parallel, covered by conductive core, covered by two layers of insulation, covered by shield, covered by jacket to form a flat cable. |
|
Shield | Required. |
|
Jacket | TPE, 32 mils minimum average thickness, 26 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|