APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21715 Issued:2010-09-03
Revised:2012-03-31
Style 21715 Multiconductor Cable with Extruded Non-Integral Jacket.

Rating80 deg C, 300 Vac, Cable flame.
Conductor17 or 16 AWG, solid or stranded. Conductive core - Extruded TPE compound filled with special carbon, provided over each conductor and between conductors. Not evaluated as self-regulating heating core.
InsulationInner Insulation - Extruded TPU, 12 mils minimum average thickness, 11 mils minimum thickness at any point. Outer Insulation - Extruded TPE, 18 mils minimum average thickness, 16 mils minimum thickness at any point. Each insulation layer separable.
AssemblyTwo conductors laid parallel, covered by conductive core, covered by two layers of insulation, covered by shield, covered by jacket to form a flat cable.
ShieldRequired.
JacketExtruded TPE.
Diameter of cableMinimumMinimum at any point
under jacket inchesaverage milspoint mils
0.700 or less3226
0.701 - 1.0004536
1.001 - 1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024