Rating | 105 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 50 AWG - 10 AWG, solid or stranded. |
|
Insulation | Extruded TPES - THERMOPLASTIC POLYESTER, 9 mils min average, 8 mils min at any point.
See Facing Page for Compound. |
|
Assembly | Two insulated conductors laid parallel or two or more insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Al/Polyester tape or metal braid provided under the overall jacket. |
|
Jacket | Extruded PVC, 30 mils min average, 24 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances. |
|