Rating | 105 deg C, 300 Vac, No Flame Rating. |
|
Conductor | 50 AWG - 10 AWG min. solid or stranded round. |
|
Insulation | Extruded TPES - THERMOPLASTIC POLYESTER, 9 mils min average, 8 mils min at any point. See Facing Page for Compound. |
|
Assembly | Two insulated conductors laid parallel or two or more insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional - Metal tape or braid. |
|
Jacket | Extruded PVC, 30 mils min average, 24 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For Further Processing as Resistance Heater Wire where the acceptability has been determined by Underwriters Laboratories Inc.. |
|