APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21729 Issued:2010-10-05
Revised:2011-09-28
Style 21729 Multiconductor Cable with Extruded Non-Integral Jacket

Rating90 deg C, 300 V
Conductor50 AWG - 10 AWG min. solid or stranded round.
InsulationETFE, 9 mils min average, 8 mils min at any point.
AssemblyTwo insulated conductors laid parallel or two or more insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional - A metal braid and/or a metal tape shield may be provided under the jacket.
JacketPUR - POLYURETHANE, 16 mils min average, 13 mils minimum at any point. See Facing Page for Compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing as Resistance Heater Wire where the acceptability has been determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024