APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21733 Issued:2010-10-20
Revised:2011-10-20
Style 21733 Multi-conductor cable using non-integral jacket.

Rating90 deg C, 300 V, Cable flame.
Conductor50 AWG - 10 AWG min. solid or stranded round.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo insulated conductors laid parallel or two or more insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldA metal tape and/or braid shall be provided under the jacket.
JacketExtruded PUR - POLYURETHANE, See Facing Page for Compound.
Dia of Cable under jacketMin averageMinimum at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnect of appliances.

UL and the UL Logo are trademarks of UL LLC © 2024