Jacketed Wire.
Rating
90 deg C, 1500 Vac, Horizontal flame.
Conductor
40 AWG - 1000 kcmil, solid or stranded.
Insulation
TPE, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
Assembly
Two or more insulated conductors. Fillers optional.
Shield
Optional.
Covering
Optional.
Jacket
PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal wiring.