APPLIANCE WIRING MATERIAL
Subj.758
Section
2
Page
21740
Issued:
2011-03-18
Revised:
2011-03-18
Style
21740
Jacketed Cable.
Rating
80 deg C, 30 Vac, Horizontal flame.
Insulation
Labeled or complying with manufacturer's AWM procedure with minimum rating 80 deg C, 30 Vac..
Assembly
Two or more insulated conductors. Fillers optional.
Shield
Optional.
Covering
Optional.
Jacket
PVC, 7 mils minimum average thickness, 6 mils minimum thickness at any point.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Internal wiring.
UL and the UL Logo are trademarks of UL LLC © 2025