APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21770 Issued:2011-04-06
Revised:2011-04-06
Style 21770 Jacketed Cable

Rating105 deg C, -40 deg C(Optional), 1000 V,60C or 80C Oil(Optional), Horizontal flame.
Conductor50 AWG - 10 AWG, solid or stranded round
InsulationLabeled.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional inner layer.
JacketTPU - See Facing Page for Compound, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances.
 
UL and the UL Logo are trademarks of UL LLC © 2024