APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21771 Issued:2011-05-06
Revised:2011-05-06
Style 21771 Jacketed cable

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationPVC, 25 mils minimum average thickness, 22 mils minimum thickness at any point. SRPVC, 10 mils minimum average thickness, 9 mils minimum thickness at any and point. HDPE, 10 mils minimum average thickness, 9 mils minimum thickness at any point.
AssemblyTwo jacketed cables laid parallel and bonded together or joined by an interconnecting web. Cable 1 consists of two or more conductors employing PVC insulation and overall PVC jacket. Cable 2 consists of 1 or more conductors employing HDPE insulation and 1 or more conductors employing SRPVC insulation, shield and overall PVC jacket.
ShieldOptional.
CoveringOptional.
BraidOptional.
JacketPVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.
 
UL and the UL Logo are trademarks of UL LLC © 2024